DWT Based Detection of Epileptic Seizure From EEG Signals Using Naive Bayes and k NN Classifiers
Rs4,500.00
10000 in stock
SupportDescription
Automatic artifact rejection is needed for effective real time inspection because manual rejection is time consuming. In this paper, a novel technique (Automatic Wavelet Independent Component Analysis, AWICA) for automatic EEG artifact removal is presented. Through AWICA we claim to improve the performance and fully automate the process of artifact removal from scalp EEG. AWICA is based on the joint use of the Wavelet Transform and of ICA: it consists of a two-step procedure relying on the concepts of kurtosis and Renyi’s entropy. Both synthesized and real EEG data are processed by AWICA and the results achieved were compared to the ones obtained by applying to the same data the “wavelet enhanced” ICA method recently proposed by other authors. Simulations illustrate that AWICA compares favorably to the other technique. The method here proposed is shown to yield improved success in terms of suppression of artifact components while reducing the loss of residual informative data, since the components related to relevant EEG activity are mostly preserved.